Loading...

Organization Parameters

Comments

5 comments

  • Sean Tame

    Regarding Org Parm CA EV80 - the note indicates that the values to switch the behaviour are:

    Y / <blank>

    OR

    N / <invalid>

    How does v20 differentiate between N and <blank> on a checkbox?  I am not sure how to set the value to N 

  • Maggie U.

    Hi Sean,

    I assume you are referring to the Contract Configuration screen - you will want to have the check box unchecked to set the value to N.

    Thanks,

    Maggie

  • Sean Tame

    Hi Maggie - yes.

    That's what I thought but Unchecked seems to be the same as <blank> and therefore behaves the same as Y.  I had to go via v19 and physically enter N into the Alphanumeric value.

    I think it needs to be changed so that <blank> is the same as No rather than Yes.

  • Megan Eve

    Is this something we can find in the "USI about" from the dashboard or does our consultant need to provide these to us?

    • Application - Two character code provided by Ungerboeck Software.
    • Code - Three digit numeric code provided by Ungerboeck Software.

     

  • Ryan G.

    Hi Megan Eve!

    Org Parameters should really only be added under the advice of Ungerboeck. Its probably best to loop your consultant in on this one.

    Thanks!

    Ryan

Please sign in to leave a comment.